Human waste treatment facilities odor control
Human Waste Treatment Facilities Odor Control at Changwon Plant
Challenge
- Changwon plant treats 240tons/day of human waste and 18tons/day of sludge. H2S concentration up to 14.3ppm.
Solution
- One odor control system of Standard type Yusung Wet-Scrubber with caustic soda, sodium hypochlorite scrubbing liquid
- FOR one Human waste treatment facility of 200㎥/min
Result
- One wet scrubber installed in 2014 treats 200㎥/min of foul air.